<?xml version="1.0" encoding="UTF-8"?><?xml-model type="application/xml-dtd" href="http://jats.nlm.nih.gov/publishing/1.1d3/JATS-journalpublishing1.dtd"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.1d3 20150301//EN" "http://jats.nlm.nih.gov/publishing/1.1d3/JATS-journalpublishing1.dtd">
<article xmlns:ali="http://www.niso.org/schemas/ali/1.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.1d3" specific-use="Marcalyc 1.2" article-type="research-article" xml:lang="es">
<front>
<journal-meta>
<journal-id journal-id-type="redalyc">2738</journal-id>
<journal-title-group>
<journal-title specific-use="original" xml:lang="es">Archivos de Medicina (Col)</journal-title>
<abbrev-journal-title abbrev-type="publisher" xml:lang="es">Arch Med</abbrev-journal-title>
</journal-title-group>
<issn pub-type="ppub">1657-320X</issn>
<issn pub-type="epub">2339-3874</issn>
<publisher>
<publisher-name>Universidad de Manizales</publisher-name>
<publisher-loc>
<country>Colombia</country>
<email>cim@umanizales.edu.co</email>
</publisher-loc>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="art-access-id" specific-use="redalyc">273865670003</article-id>
<article-id pub-id-type="doi">https://doi.org/10.30554/archmed.21.1.3809.2021</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Artículos de Investigación</subject>
</subj-group>
</article-categories>
<title-group>
<article-title xml:lang="es">
<bold>Supervivencia en pacientes con falla cardiaca y desfibrilador automático implantable en una unidad de electrofisiología de Pereira, Colombia</bold>
</article-title>
<trans-title-group>
<trans-title xml:lang="en">Survival in patients with heart failure and implantable cardioverter-defibrillator in an electrophysiological unit in Pereira, Colombia</trans-title>
</trans-title-group>
</title-group>
<contrib-group>
<contrib contrib-type="author" corresp="no">
<contrib-id contrib-id-type="orcid">https://orcid.org/0000-0003-3229-435X</contrib-id>
<name name-style="western">
<surname>Arango-Franco</surname>
<given-names>Ricardo</given-names>
</name>
<xref ref-type="aff" rid="aff1"/>
<email>riarfra@hotmail.es</email>
</contrib>
<contrib contrib-type="author" corresp="no">
<contrib-id contrib-id-type="orcid">https://orcid.org/ 0000-0003-3515-8572</contrib-id>
<name name-style="western">
<surname>Martínez</surname>
<given-names>José-William</given-names>
</name>
<xref ref-type="aff" rid="aff2"/>
<email>jose01william@utp.edu.co</email>
</contrib>
<contrib contrib-type="author" corresp="no">
<contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-4596-145X</contrib-id>
<name name-style="western">
<surname>Sosa-Urrea</surname>
<given-names>Juan-David</given-names>
</name>
<xref ref-type="aff" rid="aff3"/>
<email>juancho77@utp.edu.co</email>
</contrib>
<contrib contrib-type="author" corresp="no">
<name name-style="western">
<surname>Marín-Medina</surname>
<given-names>Daniel-Stiven</given-names>
</name>
<xref ref-type="aff" rid="aff4"/>
<email>cercaylejos@utp.edu.co</email>
</contrib>
<contrib contrib-type="author" corresp="no">
<contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-7089-7824</contrib-id>
<name name-style="western">
<surname>Orozco-Hernández</surname>
<given-names>Juan-Pablo</given-names>
</name>
<xref ref-type="aff" rid="aff5"/>
<email>jporozco1994@utp.edu.co</email>
</contrib>
<contrib contrib-type="author" corresp="no">
<contrib-id contrib-id-type="orcid">https://orcid.org/0000-0001-8690-7794</contrib-id>
<name name-style="western">
<surname>Martínez-Muñoz</surname>
<given-names>Manuel-Andrés</given-names>
</name>
<xref ref-type="aff" rid="aff6"/>
<email>maanmartinez@utp.edu.co</email>
</contrib>
<contrib contrib-type="author" corresp="no">
<contrib-id contrib-id-type="orcid">https://orcid.org/0000-0003-4327-2439</contrib-id>
<name name-style="western">
<surname>Henao-Martínez</surname>
<given-names>Juan-Fernando</given-names>
</name>
<xref ref-type="aff" rid="aff7"/>
<email>juanferhm@utp.edu.co</email>
</contrib>
<contrib contrib-type="author" corresp="no">
<contrib-id contrib-id-type="orcid">https://orcid.org/ 0000-0002-8913-7729</contrib-id>
<name name-style="western">
<surname>Sánchez-Duque</surname>
<given-names>Jorge-Andrés</given-names>
</name>
<xref ref-type="aff" rid="aff8"/>
<email>jorandsanchez@utp.edu.co.</email>
</contrib>
</contrib-group>
<aff id="aff1">
<institution content-type="original">Médico Internista, Universidad Tecnológica de Pereira, Pereira, Risaralda, Colombia. ORCID: 0000-0003-3229-435X. Correo e.: riarfra@hotmail.es.</institution>
<institution content-type="orgname">Universidad Tecnológica de Pereira</institution>
<country country="CO">Colombia</country>
</aff>
<aff id="aff2">
<institution content-type="original">Médico, Doctor en Epidemiología, Docente titular Universidad Tecnológica de Pereira, Pereira, Colombia. Grupo de Investigación Epidemiologia, Salud y Violencia, Facultad de Ciencias de la Salud, Universidad Tecnológica de Pereira, Pereira, Colombia. ORCID: 0000-0003-3515-8572. Correo e.: jose01william@utp.edu.co.</institution>
<institution content-type="orgname">Universidad Tecnológica de Pereira</institution>
<country country="CO">Colombia</country>
</aff>
<aff id="aff3">
<institution content-type="original">Médico. Grupo de Investigación Epidemiologia, Salud y Violencia, Facultad de Ciencias de la Salud, Universidad Tecnológica de Pereira, Pereira, Colombia. ORCID: 0000-0002-4596-145X. Correo e.: juancho77@utp.edu.co.</institution>
<institution content-type="orgname">Universidad Tecnológica de Pereira, Pereira</institution>
<country country="CO">Colombia</country>
</aff>
<aff id="aff4">
<institution content-type="original">Médico. Grupo de Investigación Epidemiologia, Salud y Violencia, Facultad de Ciencias de la Salud, Universidad Tecnológica de Pereira, Pereira, Colombia. ORCID: 0000-0002-9077-6309. Correo e.: cercaylejos@utp.edu.co</institution>
<institution content-type="orgname">Universidad Tecnológica de Pereira</institution>
<country country="CO">Colombia</country>
</aff>
<aff id="aff5">
<institution content-type="original">Médico. Grupo de Investigación Epidemiologia, Salud y Violencia, Facultad de Ciencias de la Salud, Universidad Tecnológica de Pereira, Pereira, Colombia. ORCID: 0000-0002-7089-7824. Correo e.: jporozco1994@utp.edu.co.</institution>
<institution content-type="orgname">Universidad Tecnológica de Pereira</institution>
<country country="CO">Colombia</country>
</aff>
<aff id="aff6">
<institution content-type="original">Médico. Grupo de Investigación Epidemiologia, Salud y Violencia, Facultad de Ciencias de la Salud, Universidad Tecnológica de Pereira, Pereira, Colombia. ORCID: 0000-0001-8690-7794. Correo e.: maanmartinez@utp.edu.co.</institution>
<institution content-type="orgname">Universidad Tecnológica de Pereira</institution>
<country country="CO">Colombia</country>
</aff>
<aff id="aff7">
<institution content-type="original">Médico. Grupo de Investigación Epidemiologia, Salud y Violencia, Facultad de Ciencias de la Salud, Universidad Tecnológica de Pereira, Pereira, Colombia. ORCID: 0000-0003-4327-2439. Correo e.: juanferhm@utp.edu.co. 8 Médico. </institution>
<institution content-type="orgname">Universidad Tecnológica de Pereira</institution>
<country country="CO">Colombia</country>
</aff>
<aff id="aff8">
<institution content-type="original">Médico. Grupo de Investigación Epidemiologia, Salud y Violencia, Facultad de Ciencias de la Salud, Universidad Tecnológica de Pereira, Pereira,  Colombia. ORCID: 0000-0002-8913-7729. Correo e.: jorandsanchez@utp.edu.co. *Autor para correspondencia</institution>
<institution content-type="orgname">Universidad Tecnológica de Pereira</institution>
<country country="CO">Colombia</country>
</aff>
<pub-date pub-type="epub-ppub">
<season>Enero-Junio</season>
<year>2021</year>
</pub-date>
<volume>21</volume>
<issue>1</issue>
<fpage>35</fpage>
<lpage>44</lpage>
<history>
<date date-type="received" publication-format="dd mes yyyy">
<day>11</day>
<month>05</month>
<year>2020</year>
</date>
<date date-type="corrected" publication-format="dd mes yyyy">
<day>30</day>
<month>05</month>
<year>2020</year>
</date>
<date date-type="accepted" publication-format="dd mes yyyy">
<day>09</day>
<month>07</month>
<year>2020</year>
</date>
</history>
<permissions>
<ali:free_to_read/>
</permissions>
<self-uri content-type="html" xlink:href="https://revistasum.umanizales.edu.co/ojs/index.php/archivosmedicina/article/view/3809">https://revistasum.umanizales.edu.co/ojs/index.php/archivosmedicina/article/view/3809</self-uri>
<abstract xml:lang="es">
<title>Resumen</title>
<p>
<bold>Objetivo</bold>: identificar las variables clínicas que impactan en la mortalidad de los pacientes con falla cardiaca implantados con desfibrilador automático. La terapia con cardiodesfibrilador implantable busca prevenir la muerte súbita cardiaca por arritmias malignas colapsantes. <bold>Material y métodos</bold>: estudio de cohorte retrospectiva. Se incluyó a pacientes con implante de desfibrilador entre los años 2010-2012, con dispositivo funcional, historia clínica y disponibilidad de seguimiento hasta el primer trimestre del 2014.<bold> Resultados</bold>: un total de 30 pacientes fueron incluidos, con una supervivencia del 77% a los cuatro años de seguimiento. El 82,7% de los pacientes presentó cardiopatía isquémica y el promedio de la fracción de eyección ventricular izquierda fue 27,8 ± 6,3. El tiempo promedio de uso del desfibrilador fue de 2,1 años, la tasa de peligro mayor reportada fue del 6% para los días 759 y 760. Se encontró una asociación entre una duración del QRS mayor a 120 ms (HR= 7,7, IC 90%= 1,77-33,6; p=0,022), fibrilación auricular (HR= 4,2, IC 90%=1,13-15,68; p=0,072) y el uso de beta-bloqueadores (HR= 0,15, IC 90%= 0,03 – 0,64; p=0,031) con el tiempo de supervivencia. <bold>Discusión</bold>: la prevención de muerte súbita está condicionada por la optimización farmacológica, así como las anomalías estructurales y de la conducción eléctrica, por lo cual se debe aumentar el seguimiento en estos casos y el ajuste de la terapia farmacológica. <bold>Conclusiones</bold>: el uso de beta bloqueadores en pacientes con falla cardiaca con fibrilación auricular y duración del QRS mayor de 120 ms es un factor protector.</p>
</abstract>
<trans-abstract xml:lang="en">
<title>Abstract</title>
<p>
<bold>Objective</bold>: to identify the clinical variables that impact on the mortality of patients with heart failure implanted with cardioverter defibrillator. Implantable cardioverter defibrillator therapy seeks to prevent sudden cardiac death by collapsing malignant arrhythmias. <bold>Material y methods</bold>: retrospective cohort study. Patients with a defibrillator implant from the year 2010 to the year 2012 were included, with functional device, clinical history and availability of follow-up until the first quarter of 2014. <bold>Results</bold>: a total of 30 patients were included, with a 77% survival at four years of follow-up. 82.7% of the patients presented with ischemic heart disease and the mean left ventricular ejection fraction was 27.8 ± 6.3. The mean time of use of the defibrillator was 2.1 years, the reported mayor danger rate was 6% for days 759 and 760. An association was found between a QRS mayor duration at 120 ms (HR = 7.7, 90% CI = 1.77-33.6, p = 0.022), atrial fibrillation (HR = 4.2, 90% CI = 1.13-15.68, p = 0.072), and beta- blockers (HR = 0.15, 90% CI = 0.03-0.64, p = 0.031) with survival time. <bold>Discussion</bold>: the prevention of death is conditioned by pharmacological optimization, as well as structural and electrical conduction anomalies, so the monitoring and adjustment of pharmacological therapy should be increased. <bold>Conclusions</bold>: the use of beta-blockers in patients with atrial fibrillation and QRS duration greater than 120 ms is a protective factor.</p>
</trans-abstract>
<kwd-group xml:lang="es">
<title>Palabras clave</title>
<kwd>desfibriladores implantables</kwd>
<kwd>análisis de supervivencia</kwd>
<kwd>muerte súbita cardíaca</kwd>
<kwd>estimulación eléctrica</kwd>
<kwd>Colombia</kwd>
</kwd-group>
<kwd-group xml:lang="en">
<title>Keywords</title>
<kwd>defibrillator</kwd>
<kwd>survival</kwd>
<kwd>cardiac sudden death</kwd>
<kwd>electrical stimulation</kwd>
<kwd>Colombia</kwd>
</kwd-group>
<counts>
<fig-count count="6"/>
<table-count count="0"/>
<equation-count count="0"/>
<ref-count count="37"/>
</counts>
</article-meta>
</front>
<body>
<sec sec-type="intro">
<title>
<bold>Introducción</bold>
</title>
<p>La enfermedad cardiovascular es el responsable de 800.000 fallecimientos en los Estados Unidos cada año, de las cuales, aproximadamente el 50% son muertes cardiacas súbitas [<xref ref-type="bibr" rid="redalyc_273865670003_ref1">1</xref>]. A nivel mundial, se le atribuyen alrededor de 1 a 1.5 millones de defunciones [<xref ref-type="bibr" rid="redalyc_273865670003_ref2">2</xref>], representando del 15 al 20% de todas las muertes en países occidentales [<xref ref-type="bibr" rid="redalyc_273865670003_ref3">3</xref>]. La enfermedad coronaria, la cardiomiopatía valvular y arritmogénica son las principales causas de muerte de origen cardíaco [<xref ref-type="bibr" rid="redalyc_273865670003_ref3">3</xref>]. Las arritmias ventriculares son la principal causa de muerte súbita cardiaca y esta es la razón por la cual se implanta un desfibrilador automático [<xref ref-type="bibr" rid="redalyc_273865670003_ref4">4</xref>]. Este dispositivo, desde su introducción en 1980 para uso clínico en Estados Unidos, ha sido utilizado para la prevención de la muerte súbita cardiaca tanto primaria como secundaria. El desfibrilador automático ha mostrado reducción de la mortalidad en pacientes con insuficiencia cardíaca (HR=0,66, IC 95%= 0,56,0,78; p&lt;0,001) [<xref ref-type="bibr" rid="redalyc_273865670003_ref5">5</xref>,<xref ref-type="bibr" rid="redalyc_273865670003_ref6">6</xref>], cardiopatía no isquémica (HR=0,78, IC 95%= 0,66-0,92; P = 0,003) (<xref ref-type="bibr" rid="redalyc_273865670003_ref7">7</xref>), enfermedad coronaria e infarto agudo de miocardio (HR=0,46, IC 95%=0,26-0,82; p=0,009) [<xref ref-type="bibr" rid="redalyc_273865670003_ref8">8</xref>], muerte súbita reanimada [<xref ref-type="bibr" rid="redalyc_273865670003_ref9">9</xref>], patologías congénitas [<xref ref-type="bibr" rid="redalyc_273865670003_ref10">10</xref>], algunas patologías adquiridas como la enfermedad chagásica y miocardiopatías de otras etiologías [<xref ref-type="bibr" rid="redalyc_273865670003_ref11">11</xref>], en las cuales se busca reducir la mortalidad por un evento arrítmico primario [<xref ref-type="bibr" rid="redalyc_273865670003_ref5">5</xref>,<xref ref-type="bibr" rid="redalyc_273865670003_ref8">8</xref>,<xref ref-type="bibr" rid="redalyc_273865670003_ref12">12</xref>] o la mortalidad global asociada [<xref ref-type="bibr" rid="redalyc_273865670003_ref9">9</xref>,<xref ref-type="bibr" rid="redalyc_273865670003_ref13">13</xref>].</p>
<p>El implante del desfibrilador automático ha mostrado una reducción entre 5 al 15% en la mortalidad global [<xref ref-type="bibr" rid="redalyc_273865670003_ref5">5</xref>,<xref ref-type="bibr" rid="redalyc_273865670003_ref6">6</xref>,<xref ref-type="bibr" rid="redalyc_273865670003_ref7">7</xref>,<xref ref-type="bibr" rid="redalyc_273865670003_ref8">8</xref>,<xref ref-type="bibr" rid="redalyc_273865670003_ref9">9</xref>] y ha sido aceptado como parte del manejo avanzado de la insuficiencia cardiaca en diferentes países del mundo [<xref ref-type="bibr" rid="redalyc_273865670003_ref14">14</xref>,<xref ref-type="bibr" rid="redalyc_273865670003_ref15">15</xref>]. El cardiodesfibrilador es una terapia costo efectiva y se reportan valores cercanos a los US $100000 por año ganado ajustados por calidad de vida [<xref ref-type="bibr" rid="redalyc_273865670003_ref16">16</xref>].</p>
<p>En Latinoamérica, el desfibrilador automático implantable es usado principalmente para prevención secundaria [<xref ref-type="bibr" rid="redalyc_273865670003_ref17">17</xref>]. La experiencia en Uruguay muestra una supervivencia similar a la reportada en otros ensayos clínicos, con el 80% de los pacientes vivos a los cinco años de seguimiento [<xref ref-type="bibr" rid="redalyc_273865670003_ref17">17</xref>]. En Colombia, la terapia se encuentra disponible desde el año 2009 en el plan de beneficios de los afiliados al sistema general de seguridad en salud [<xref ref-type="bibr" rid="redalyc_273865670003_ref18">18</xref>]. Existen pocos estudios en Colombia del comportamiento clínico de pacientes con falla cardiaca con desfibrilador automático implantable y ninguno ha evaluado su supervivencia como terapia única (sin resincronizador cardiaco) [<xref ref-type="bibr" rid="redalyc_273865670003_ref19">19</xref>,<xref ref-type="bibr" rid="redalyc_273865670003_ref20">20</xref>]. Debido a esto, este estudio buscó identificar las variables clínicas que impactan en la mortalidad de los pacientes con falla cardiaca implantados con desfibrilador automático de una unidad de electrofisiología en Pereira, Colombia.</p>
</sec>
<sec sec-type="materials|methods">
<title>
<bold>Materiales y métodos</bold>
</title>
<p>
<bold>Diseño</bold>: se realizó un estudio de cohorte retrospectiva en pacientes con cardiodesfibrilador implantado entre los años 2010-2012. Con un tiempo de seguimiento de 4 años. El desenlace fue la muerte del paciente.</p>
<p>
<bold>			Población</bold>: los criterios de inclusión fueron: 1) diagnóstico de falla cardiaca según guías de práctica clínica [<xref ref-type="bibr" rid="redalyc_273865670003_ref21">21</xref>, <xref ref-type="bibr" rid="redalyc_273865670003_ref22">22</xref>] mayores de 18 años, 3) con implante de desfibrilador automático de primera vez, entre el 1 de enero del 2010 al 31 de diciembre del 2012, 4) con un dispositivo funcional, 5) disponibilidad de seguimiento en el tiempo. Se excluyeron seis pacientes por información incompleta a pesar de realizar entrevista telefónica y visita domiciliaria.</p>
<p>
<bold>			Recolección de datos:</bold> se creó una base de datos en Excel 2010 versión licenciada, a partir de la historia clínica y otros registros médicos, sometidos a control de calidad de la información durante la obtención, compilación y procesamiento de los datos para su validación y análisis.</p>
<p>
<bold>			Definiciones operativas:</bold> clase funcional según clasificación de la New York Heart Association [<xref ref-type="bibr" rid="redalyc_273865670003_ref14">14</xref>], QRS amplio o estrecho según concepto médico explícito consignado en la historia clínica, electrocardiograma previo, presencia o ausencia de bloqueo de rama observado o descrito, tasa de filtración glomerular estimada con el modelo CKD–EPI [<xref ref-type="bibr" rid="redalyc_273865670003_ref22">22</xref>] y estadio de enfermedad renal crónica acorde a la clasificación de la National Kidney Foundation [<xref ref-type="bibr" rid="redalyc_273865670003_ref18">18</xref>]. Se incluyó variables demográficas, historial médico, fecha de implante del dispositivo, terapia farmacológica previa y posterior al implante, fecha de entrevista y estado del paciente al momento de la entrevista.</p>
<p>
<bold>			Análisis estadístico</bold>: el procesamiento se realizó con el software STATA 14. Las características de base fueron descritas utilizando medias, medianas y rangos intercuartílicos para las variables medidas en escala numérica. Se empleó frecuencias y proporciones para variables medidas en escala nominal.</p>
<p>Para el análisis de supervivencia se utilizó el método de Kaplan-Meier con el cual se pudo determinar las probabilidades acumuladas de muerte por cualquier causa. Se define como censura el estar vivo al tiempo de corte. En el análisis bivariado se compararon las curvas de supervivencia y se realizaron las pruebas de hipótesis usando la prueba de Log Rank Test ajustada por el test de Wilcoxon. El análisis multivariado se realizó por regresión logística para distribución tipo Weibull y se determinó el hazard en el tiempo [<xref ref-type="bibr" rid="redalyc_273865670003_ref23">23</xref>], con un nivel de confianza del 90%.</p>
<p>Este estudio fue aprobado por parte del comité de bioética de la Universidad Tecnológica de Pereira en la categoría de “investigación sin riesgo”, según la resolución No. 8430 de 1993 del Ministerio de Salud de Colombia, que establece las normas científicas, técnicas y administrativas para la investigación en salud. Se obtuvo consentimiento informado verbal de cada uno de los pacientes del estudio.</p>
</sec>
<sec sec-type="results">
<title>
<bold>Resultados</bold>
</title>
<p>Se incluyó un total de 30 pacientes con implante de desfibrilador automático, con una mediana de edad de 70 años (61-76 años), 27 (90%) de los pacientes eran de sexo masculino, 12 (40%) tenían una clase funcional I y II de la NYHA, 83,3% tuvieron cardiopatía isquémica de base y 29 (96,7%) pacientes se encontraban en estadio C de insuficiencia cardíaca según la clasificación de la <bold>American Heart Association</bold> (<xref ref-type="fig" rid="gf1">Tabla 1</xref>).</p>
<p>
<fig id="gf1">
<label>
<bold>Tabla 1</bold>
</label>
<caption>
<title>
<bold>Características clínicas de los pacientes previas al implante del desfibrilador automático</bold>
</title>
<p>*RIC= Rango Intercuartílico</p>
<p>**Según la clasificación de New York Heart Association (NYHA).</p>
<p>NYHA: clase funcional de la New York Heart Association.</p>
<p>***FEVI: fracción de eyección ventricular izquierda.</p>
</caption>
<alt-text>Tabla 1 Características clínicas de los pacientes previas al implante del desfibrilador automático</alt-text>
<graphic xlink:href="273865670003_gf2.png" position="anchor" orientation="portrait"/>
<attrib>elaboración propia.</attrib>
</fig>
</p>
<p>
<bold>Comorbilidades</bold>
</p>
<p>8 (27,3%) pacientes tuvieron de 1 a 3 comorbilidades, 21 (69,3%) tuvieron de 4 a 7 comorbilidades. Sólo 2 pacientes no tenían arritmias, 23 (78,6%) tenían alguna arritmia y 9 (28,6%) presentaban de forma concomitante, una arritmia ventricular y una supraventricular (<xref ref-type="fig" rid="gf2">Tabla 2</xref>). En la serie no se presentó estados avanzados de enfermedad renal crónica</p>
<p>
<fig id="gf2">
<label>
<bold>Tabla 2</bold>
</label>
<caption>
<title>
<bold>Antecedentes patológicos previos a la terapia electrofisiológica</bold>
</title>
<p>*La Tasa de Filtración Glomerular se estimó con la ecuación del modelo CKD-EPI (Chronic Kidney Disease Epidemiology Collaboration) en (ml/kg/m2)</p>
<p>** DE= Desviación Estándar</p>
<p>*** Según la clasificación K/DOQI.</p>
</caption>
<alt-text>Tabla 2 Antecedentes patológicos previos a la terapia electrofisiológica</alt-text>
<graphic xlink:href="273865670003_gf3.png" position="anchor" orientation="portrait"/>
<attrib>Elaboración propia.</attrib>
</fig>
</p>
<p>
<bold>Tratamiento farmacológico</bold>
</p>
<p>23 (75,9%) pacientes usaban algún diurético, 26 (86,2%) recibieron iECA o ARAII. 4 (13,3%) pacientes usaban anticoagulantes, donde el 10% tenía warfarina. 21 (70%) pacientes recibieron beta-bloqueadores, siendo el carvedilol el de mayor prescripción (46,7%).</p>
<p>
<bold>Análisis de supervivencia</bold>
</p>
<p>Durante el tiempo de seguimiento fallecieron 7 pacientes, siendo todas las causas de muerte debidas a muerte súbita cardiaca a excepción de un paciente que falleció por sepsis urinaria. El tiempo de uso de cardiodesfibrilador promedio fue de 2,1 años (IC 95% = 1,74 – 2,49). No se halló una asoc</p>
<p>Durante el tiempo de seguimiento fallecieron 7 pacientes, siendo todas las causas de muerte debidas a muerte súbita cardiaca a excepción de un paciente que falleció por sepsis urinaria. El tiempo de uso de cardiodesfibrilador promedio fue de 2,1 años (IC 95% = 1,74 – 2,49). No se halló una asociación significativa en la supervivencia con ninguna de las siguientes variables: estado de insuficiencia cardiaca, fracción de eyección, arritmia ventricular, cardiopatía isquémica, enfermedad coronaria, hipertensión arterial, enfermedad arterial periférica, enfermedad pulmonar obstructiva crónica, enfermedad renal crónica o antecedente de revascularización quirúrgica.</p>
<p>Se encontró una diferencia significativa ajustando por el antecedente de fibrilación auricular <bold>(ver Figura 1, <xref ref-type="fig" rid="gf3">panel A</xref>. p=0,006 por log rank test ajustado por Wilcoxon).</bold> Los pacientes sin fibrilación auricular tienen una supervivencia del 86% para el primer año después del implante, la cual se estabiliza hasta el final de seguimiento. Por otro lado, en los pacientes con fibrilación auricular durante los primeros 16 meses se vio una supervivencia del 50% y una tasa de peligro del 40% para el mes 25.</p>
<p>La morfología del QRS en el análisis de supervivencia de Kaplan- Meier mostró una diferencia significativa entre los pacientes con QRS amplio y estrecho<bold> (figura 1 <xref ref-type="fig" rid="gf7">panel B</xref>, p=0,003 por log Rank test ajustado por Wilcoxon)</bold>. Los pacientes con QRS estrecho tienen una tasa de peligro del 13% para el mes 26 que se estabilizó hasta el mes 43 y para los meses 25 a 26 tienen una tasa de peligro del 8%. De los pacientes con QRS amplio, el 50% mueren en el primer año, con una tasa de peligro de 18%, la cual permanece estable hasta la terminación del estudio</p>
<p>
<fig id="gf3">
<label>
<bold>Panel A</bold>
</label>
<caption>
<title>
<bold>Estimaciones de Kaplan-Meier de la probabilidad acumulada de muerte por cualquier causa de los pacientes con implante de desfibrilador automático (Panel A)</bold>
</title>
</caption>
<alt-text>Panel A Estimaciones de Kaplan-Meier de la probabilidad acumulada de muerte por cualquier causa de los pacientes con implante de desfibrilador automático (Panel A)</alt-text>
<graphic xlink:href="273865670003_gf4.png" position="anchor" orientation="portrait"/>
<attrib>Elaboración propia</attrib>
</fig>
</p>
<p>
<fig id="gf7">
<label>
<bold>Panel B</bold>
</label>
<caption>
<title>
<bold>Estimaciones de Kaplan-Meier de la probabilidad acumulada de muerte por cualquier causa de los pacientes con implante de desfibrilador automático (Panel B )</bold>
</title>
</caption>
<alt-text>Panel B Estimaciones de Kaplan-Meier de la probabilidad acumulada de muerte por cualquier causa de los pacientes con implante de desfibrilador automático (Panel B )</alt-text>
<graphic xlink:href="273865670003_gf6.png" position="anchor" orientation="portrait"/>
<attrib>Elaboración propia</attrib>
</fig>
</p>
<p>
<fig id="gf8">
<label>
<bold>Panel C</bold>
</label>
<caption>
<title>
<bold>Estimaciones de Kaplan-Meier de la probabilidad acumulada de muerte por cualquier causa de los pacientes con implante de desfibrilador automático (Panel C)</bold>
</title>
<p>Elaboración propia</p>
</caption>
<alt-text>Panel C Estimaciones de Kaplan-Meier de la probabilidad acumulada de muerte por cualquier causa de los pacientes con implante de desfibrilador automático (Panel C)</alt-text>
<graphic xlink:href="273865670003_gf7.png" position="anchor" orientation="portrait"/>
<attrib>Elaboración propia</attrib>
</fig>
</p>
<p>Se obtuvo una diferencia significativa en el uso de betabloqueadores en el análisis de supervivencia <bold>(ver figura 1 <xref ref-type="fig" rid="gf8">panel C</xref>, p= 0,03 por log Rank test ajustado por Wilcoxon)</bold>. Los pacientes medicados con beta-bloqueadores tienen un mayor riesgo de muerte del 6% para el primer año, el cual aumenta levemente logrando un riesgo de muerte acumulado del 12% hasta el final del seguimiento. Para los días 485 y 486 tienen una tasa de peligro del 5%. Por otro lado, el 36% de los pacientes que no usan beta-bloqueadores mueren durante el primer año de seguimiento con una tasa de peligro del 18%. El riesgo de muerte sigue constante al continuar el seguimiento, aunque para los días 759 y 760 se encuentra una tasa de peligro de 60%.</p>
<p>
<bold>Análisis multivariado</bold>
</p>
<p>El tiempo de supervivencia tuvo una distribución tipo Weibull (Valor K=1,205). A partir del modelo se encontró una asociación entre una duración del QRS mayor a 120 ms (HR= 7,7, IC 90%= 1,77 -33,6; p=0,022), la fibrilación auricular (HR= 4,2, IC 90%=1,13-15,68; p=0,072) y el uso de beta-bloqueadores (HR= 0,15, IC 90%= 0,03 – 0,64; p=0,031) con el tiempo de supervivencia, con un nivel de confianza del 90%. Los beta-bloqueadores utilizados fueron: carvedilol y succinato de metoprolol. Ver <xref ref-type="fig" rid="gf9">Tabla 3</xref>.</p>
<p>
<fig id="gf9">
<label>
<bold>Tabla 3</bold>
</label>
<caption>
<title>
<bold>Regresión logística de los factores asociados a la mortalidad en pacientes con falla cardiaca y desfibrilador automático implantable del estudio</bold>
</title>
</caption>
<alt-text>Tabla 3 Regresión logística de los factores asociados a la mortalidad en pacientes con falla cardiaca y desfibrilador automático implantable del estudio</alt-text>
<graphic xlink:href="273865670003_gf8.png" position="anchor" orientation="portrait"/>
<attrib>Elaboración propia</attrib>
</fig>
</p>
</sec>
<sec sec-type="discussion">
<title>
<bold>Discusión</bold>
</title>
<p>Las características clínicas observadas son similares a las de los principales ensayos clínicos realizados desde 1996, sin embargo, estos pacientes tienen mayor carga de enfermedad isquémica y menor fracción de eyección, lo que representa un riesgo mayor de mortalidad [<xref ref-type="bibr" rid="redalyc_273865670003_ref5">5</xref>,<xref ref-type="bibr" rid="redalyc_273865670003_ref6">6</xref>,<xref ref-type="bibr" rid="redalyc_273865670003_ref7">7</xref>,<xref ref-type="bibr" rid="redalyc_273865670003_ref8">8</xref>].</p>
<p>En estos pacientes la terapia farmacológica se encuentra optimizada a la luz de las guías actuales basadas en la evidencia para el tratamiento de la cardiopatía isquémica y la insuficiencia cardiaca, lo que no estaba presente en los estudios anteriores al año 1999 cuando no se conocían los resultados de los grandes ensayos sobre betabloqueadores y mortalidad en falla cardiaca [<xref ref-type="bibr" rid="redalyc_273865670003_ref24">24</xref>,<xref ref-type="bibr" rid="redalyc_273865670003_ref25">25</xref>,<xref ref-type="bibr" rid="redalyc_273865670003_ref26">26</xref>].</p>
<p>El betabloqueo en el paciente con fibrilación auricular como lo mostró el modelo, y aún más cuando se analizó su asociación con la duración de QRS amplio, enmarca un escenario clínico de mayor complejidad y riesgo de muerte por la severidad de la alteración estructural y mayor carga arritmogénica, lo que demostró un riesgo de muerte de casi el doble acumulado en el primer año para estos pacientes.</p>
<p>En la presente investigación el QRS amplio (&gt;120 ms) se comportó como un factor de riesgo importante de mortalidad en estos pacientes, incrementando el riesgo hasta casi 8 veces (HR= 7,7, IC 90%= 1,77 -33,6; p=0,022) con respecto aquellos con QRS estrecho. Este ha sido un hallazgo documentado por otros autores [<xref ref-type="bibr" rid="redalyc_273865670003_ref27">27</xref>,<xref ref-type="bibr" rid="redalyc_273865670003_ref28">28</xref>], en los cuales se ha identificado como un predictor importante de mortalidad que incrementa el riesgo de muerte hasta el doble en estos pacientes y está presente en alrededor del 14-47% de los pacientes con falla cardiaca, principalmente por bloqueo de rama izquierda (25% a 36%) frente a (4% a 6%) por bloqueo de rama derecha. Por el contrario, se ha encontrado que un QRS estrecho (&lt;118 ms) es un factor protector independiente de mortalidad en esta población [<xref ref-type="bibr" rid="redalyc_273865670003_ref29">29</xref>].</p>
<p>La fibrilación auricular fue otro hallazgo importante en este estudio que se asoció a mortalidad, incrementando el riesgo más de cuatro veces (HR= 4,2, IC 90%=1,13-15,68; p=0,072) con respecto aquellos sin esta arritmia. La fibrilación auricular es la arritmia más frecuente en la práctica clínica y se ha demostrado que junto a la falla cardiaca puede incrementar el riesgo de mortalidad más del doble [<xref ref-type="bibr" rid="redalyc_273865670003_ref30">30</xref>]. Esta arritmia es tanto causa como consecuencia de la falla cardiaca; ambas condiciones comparten una fisiopatología similar y hacen parte de la epidemia del siglo XXI, incrementando morbi-mortalidad y costos al sistema de salud [<xref ref-type="bibr" rid="redalyc_273865670003_ref31">31</xref>].</p>
<p>El uso de beta-bloqueadores ha demostrado reducir la mortalidad en pacientes con falla cardiaca y fibrilación auricular (HR= 0.72, IC 95%= 0.549 to 0.945; p = 0.018) [<xref ref-type="bibr" rid="redalyc_273865670003_ref32">32</xref>], siendo un hallazgo similar al de nuestro estudio, donde los beta-bloqueadores (carvedilol y succinato de metoprolol) se comportaron como factor protector para mortalidad en estos pacientes (HR= 0,15, IC 90%= 0,03 – 0,64; p=0,031), lo cual está acorde a las guías de práctica clínica que recomiendan su uso en pacientes con falla cardiaca con fracción de eyección disminuida sin importar la presencia o no de fibrilación auricular [<xref ref-type="bibr" rid="redalyc_273865670003_ref21">21</xref>,<xref ref-type="bibr" rid="redalyc_273865670003_ref33">33</xref>].</p>
<p>En cuanto a las causas de muerte, todas ellas fueron debido a muerte súbita cardiaca, y solo una de ellas fue debida a sepsis urinaria. Estudios con mayores tamaños de muestra han encontrado que en estos pacientes la causa de muerte más frecuente fue muerte cardiaca no súbita (49%), seguida por la muerte cardiaca súbita (28%) y de causa no cardiaca (22%) [<xref ref-type="bibr" rid="redalyc_273865670003_ref34">34</xref>], sin embargo, debido al pequeño tamaño de muestra de nuestro estudio resulta difícil realizar comparaciones en este ámbito. Finalmente, dado que la presencia de estos dispositivos aumenta en adultos mayores, se requiere realizar de forma complementaria una evaluación geriátrica integral [<xref ref-type="bibr" rid="redalyc_273865670003_ref35">35</xref>], teniendo en cuenta cada dimensión del individuo como persona y especialmente la identificación de pacientes en estado terminal cuya esperanza de vida sea de seis meses o menos [<xref ref-type="bibr" rid="redalyc_273865670003_ref36">36</xref>], así como, la optimización del esquema farmacológico previniendo incurrir en polimedicación [<xref ref-type="bibr" rid="redalyc_273865670003_ref37">37</xref>].</p>
<p>Este estudio encontró tasas de peligro en una muestra pequeña con un modelo sencillo ajustado en relación a la distribución específica de los datos. Se proporciona información vital para el seguimiento de estos pacientes y la planeación de intervención puntual en los pacientes de mayor riesgo de muerte, así como el ajuste de la terapia farmacológica a niveles superiores al 95 % observado en ensayos clínicos controlados, velando por alcanzar un betabloqueo adecuado a la luz de la individualización de la terapia. Debido al pequeño tamaño muestral, la validez externa no es la mejor, pero promueve la realización de estudios multicéntricos para desarrollar estrategias de atención secundaria con información propia que tengan impacto en desenlaces importantes en los pacientes del eje geográfico cafetero en Colombia y a nivel nacional.</p>
</sec>
<sec sec-type="conclusions">
<title>
<bold>Conclusión</bold>
</title>
<p>En el paciente con falla cardiaca en terapia con cardiodesfibrilador implantable, las variables clínicas que impactan en la mortalidad son el uso de beta-bloqueadores y la coexistencia de fibrilación auricular y QRS amplio. Una vez que el paciente ha sido implantado con el desfibrilador, la mayor mortalidad a lo largo del tiempo empieza a aparecer en el primer año y la mitad del segundo año, momentos en los cuales se presentan los desenlaces de muerte en los pacientes con fibrilación auricular, QRS amplio y en aquellos sin beta bloqueador. Es en este periodo de tiempo cuando las actuaciones médicas deben enfocarse hacia un seguimiento cercano del paciente con estas características y a optimizar la terapia farmacológica con la finalidad de impactar la mortalidad.</p>
<p>
<bold>			Agradecimientos </bold>
</p>
<p>A una unidad de hemodinamia en Pereira, Risaralda y a la doctora Lynda Ivette Carvajal, electrofisióloga.</p>
<p>
<bold>			Conflictos de Interés</bold>: ninguno declarado.</p>
<p>
<bold>			Fuentes de financiación:</bold> por parte de los autores.</p>
</sec>
</body>
<back>
<ref-list>
<title>
<bold>Literatura citada</bold>
</title>
<ref id="redalyc_273865670003_ref1">
<label>1.</label>
<mixed-citation>1.	Kamp NJ, Al-Khatib SM. <bold>The subcutaneous implantable cardioverter-defibrillator in review</bold>.<italic> Am Heart J</italic>. 2019; 217:131-9. DOI: 10.1016/j.ahj.2019.08.010</mixed-citation>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kamp</surname>
<given-names>NJ</given-names>
</name>
<name>
<surname>Al-Khatib</surname>
<given-names>SM</given-names>
</name>
</person-group>
<article-title>The subcutaneous implantable cardioverter-defibrillator in review</article-title>
<source>Am Heart J</source>
<year>2019</year>
<volume>217</volume>
<fpage>131</fpage>
<lpage>139</lpage>
<pub-id pub-id-type="doi">10.1016/j.ahj.2019.08.01</pub-id>
</element-citation>
</ref>
<ref id="redalyc_273865670003_ref2">
<label>2.</label>
<mixed-citation>2.	Bob-Manuel T, Jenkins JS, Morin DP. <bold>Non-arrhythmic causes of sudden death: A comprehensive review</bold>. <italic>Prog Cardiovasc Dis</italic>. 2019; 62(3):265-71. DOI: 10.1016/j.pcad.2019.05.004</mixed-citation>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bob-Manuel</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Jenkins</surname>
<given-names>JS</given-names>
</name>
<name>
<surname>Morin</surname>
<given-names>DP</given-names>
</name>
</person-group>
<article-title>Non-arrhythmic causes of sudden death: A comprehensive review</article-title>
<source>Prog Cardiovasc Dis</source>
<year>2019</year>
<volume>62</volume>
<issue>3</issue>
<fpage>265</fpage>
<lpage>271</lpage>
<pub-id pub-id-type="doi">10.1016/j.pcad.2019.05.004</pub-id>
</element-citation>
</ref>
<ref id="redalyc_273865670003_ref3">
<label>3.</label>
<mixed-citation>3.	Wong CX, Brown A, Lau DH, Chugh SS, Albert CM, Kalman JM, et al. <bold>Epidemiology of Sudden Cardiac Death: Global and Regional Perspectives.</bold>
<italic>Heart Lung Circ.</italic> 2019; 28(1):6-14. DOI: 10.1016/j.hlc.2018.08.026</mixed-citation>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wong</surname>
<given-names>CX</given-names>
</name>
<name>
<surname>Brown</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Lau</surname>
<given-names>DH</given-names>
</name>
<name>
<surname>Chugh</surname>
<given-names>SS</given-names>
</name>
<name>
<surname>Albert</surname>
<given-names>CM</given-names>
</name>
<name>
<surname>Kalman</surname>
<given-names>JM</given-names>
</name>
</person-group>
<article-title>Epidemiology of Sudden Cardiac Death: Global and Regional Perspectives</article-title>
<source>Heart Lung Circ</source>
<year>2019</year>
<volume>28</volume>
<issue>1</issue>
<fpage>6</fpage>
<lpage>14</lpage>
<pub-id pub-id-type="doi">10.1016/j.hlc.2018.08.026</pub-id>
</element-citation>
</ref>
<ref id="redalyc_273865670003_ref4">
<label>4.</label>
<mixed-citation>4.	Dimos A, Xanthopoulos A, Papamichalis M, Bourazana A, Tavoularis D, Skoularigis J, et al. <bold>Sudden Arrhythmic Death at the Higher End of the Heart Failure Spectrum.</bold>
<italic>Angiology</italic>. 2020; 71(5):389-96. DOI: 10.1177/0003319719896475</mixed-citation>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Dimos</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Xanthopoulos</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Papamichalis</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Bourazana</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Tavoularis</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Skoularigis</surname>
<given-names>J</given-names>
</name>
</person-group>
<article-title>Sudden Arrhythmic Death at the Higher End of the Heart Failure Spectrum</article-title>
<source>Angiology</source>
<year>2020</year>
<volume>71</volume>
<issue>5</issue>
<fpage>389</fpage>
<lpage>396</lpage>
<pub-id pub-id-type="doi">10.1177/0003319719896475</pub-id>
</element-citation>
</ref>
<ref id="redalyc_273865670003_ref5">
<label>5.</label>
<mixed-citation>5.	Goldenberg I, Gillespie J, Moss AJ, Hall WJ, Klein H, McNitt S, et al. L<bold>ong-term benefit of primary prevention with an implantable cardioverter-defibrillator: an extended 8-year follow-up study of the Multicenter Automatic Defibrillator Implantation Trial II.</bold>
<italic>Circulation</italic>. 2010;122(13):1265-71. DOI: 10.1161/CIRCULATIONAHA.110.940148</mixed-citation>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Goldenberg</surname>
<given-names>I</given-names>
</name>
<name>
<surname>Gillespie</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Moss</surname>
<given-names>AJ</given-names>
</name>
<name>
<surname>Hall</surname>
<given-names>WJ</given-names>
</name>
<name>
<surname>Klein</surname>
<given-names>H</given-names>
</name>
<name>
<surname>McNitt</surname>
<given-names>S</given-names>
</name>
</person-group>
<article-title>Long-term benefit of primary prevention with an implantable cardioverter-defibrillator: an extended 8-year follow-up study of the Multicenter Automatic Defibrillator Implantation Trial II</article-title>
<source>Circulation</source>
<year>2010</year>
<volume>122</volume>
<issue>13</issue>
<fpage>1265</fpage>
<lpage>1271</lpage>
<pub-id pub-id-type="doi">10.1161/CIRCULATIONAHA.110.940148</pub-id>
</element-citation>
</ref>
<ref id="redalyc_273865670003_ref6">
<label>6.</label>
<mixed-citation>6.	Bardy GH, Lee KL, Mark DB, Poole JE, Packer DL, Boineau R, et al. <bold>Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure</bold>. <italic>N Engl J Med</italic>. 2005; 352(3):225-37. DOI: 10.1056/NEJMoa043399</mixed-citation>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bardy</surname>
<given-names>GH</given-names>
</name>
<name>
<surname>Lee</surname>
<given-names>KL</given-names>
</name>
<name>
<surname>Mark</surname>
<given-names>DB</given-names>
</name>
<name>
<surname>Poole</surname>
<given-names>JE</given-names>
</name>
<name>
<surname>Packer</surname>
<given-names>DL</given-names>
</name>
<name>
<surname>Boineau</surname>
<given-names>R</given-names>
</name>
</person-group>
<article-title>Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure</article-title>
<source>N Engl J Med</source>
<year>2005</year>
<volume>352</volume>
<issue>3</issue>
<fpage>225</fpage>
<lpage>237</lpage>
<pub-id pub-id-type="doi">10.1056/NEJMoa043399</pub-id>
</element-citation>
</ref>
<ref id="redalyc_273865670003_ref7">
<label>7.</label>
<mixed-citation>7.	Stavrakis S, Asad Z, Reynolds D. <bold>Implantable Cardioverter Defibrillators for Primary Prevention of Mortality in Patients With Nonischemic Cardiomyopathy: A Meta-Analysis of Randomized Controlled Trials</bold>. <italic>J Cardiovasc Electrophysiol</italic>. 2017; 28(6):659-65. DOI: 10.1111/jce.13204</mixed-citation>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Stavrakis</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Asad</surname>
<given-names>Z</given-names>
</name>
<name>
<surname>Reynolds</surname>
<given-names>D</given-names>
</name>
</person-group>
<article-title>Implantable Cardioverter Defibrillators for Primary Prevention of Mortality in Patients With Nonischemic Cardiomyopathy: A Meta-Analysis of Randomized Controlled Trials</article-title>
<source>J Cardiovasc Electrophysiol</source>
<year>2017</year>
<volume>28</volume>
<issue>6</issue>
<fpage>659</fpage>
<lpage>695</lpage>
<pub-id pub-id-type="doi">10.1111/jce.13204</pub-id>
</element-citation>
</ref>
<ref id="redalyc_273865670003_ref8">
<label>8.</label>
<mixed-citation>8.	Moss AJ, Hall WJ, Cannom DS, Daubert JP, Higgins SL, Klein H, et al. <bold>Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. Multicenter Automatic Defibrillator Implantation Trial Investigators</bold>. <italic>N Engl J Med.</italic> 1996; 335(26):1933-40. DOI: 10.1056/NEJM199612263352601</mixed-citation>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Moss</surname>
<given-names>AJ</given-names>
</name>
<name>
<surname>Hall</surname>
<given-names>WJ</given-names>
</name>
<name>
<surname>Cannom</surname>
<given-names>DS</given-names>
</name>
<name>
<surname>Daubert</surname>
<given-names>JP</given-names>
</name>
<name>
<surname>Higgins</surname>
<given-names>SL</given-names>
</name>
<name>
<surname>Klein</surname>
<given-names>H</given-names>
</name>
</person-group>
<article-title>Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. Multicenter Automatic Defibrillator Implantation Trial Investigators</article-title>
<source>N Engl J Med</source>
<year>1996</year>
<volume>335</volume>
<issue>26</issue>
<fpage>1933</fpage>
<lpage>1940</lpage>
<pub-id pub-id-type="doi">10.1056/NEJM199612263352601</pub-id>
</element-citation>
</ref>
<ref id="redalyc_273865670003_ref9">
<label>9.</label>
<mixed-citation>9.	Borne RT, Katz D, Betz J, Peterson PN, Masoudi FA.<bold> Implantable Cardioverter-Defibrillators for Secondary Prevention of Sudden Cardiac Death: A Review</bold>. <italic>J Am Heart Assoc.</italic> 2017; 6(3):e005515. DOI: 10.1161/JAHA.117.005515</mixed-citation>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Borne</surname>
<given-names>RT</given-names>
</name>
<name>
<surname>Katz</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Betz</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Peterson</surname>
<given-names>PN</given-names>
</name>
<name>
<surname>Masoudi</surname>
<given-names>FA</given-names>
</name>
</person-group>
<article-title>Implantable Cardioverter-Defibrillators for Secondary Prevention of Sudden Cardiac Death: A Review</article-title>
<source>J Am Heart Assoc</source>
<year>2017</year>
<volume>6</volume>
<issue>3</issue>
<fpage>e005515</fpage>
<lpage>e005515</lpage>
<pub-id pub-id-type="doi">10.1161/JAHA.117.005515</pub-id>
</element-citation>
</ref>
<ref id="redalyc_273865670003_ref10">
<label>10.</label>
<mixed-citation>10.	Lévesque V, Laplante L, Shohoudi A, Apers S, Kovacs AH, Luyckx K, et al. <bold>Implantable cardioverter-defibrillators and patient-reported outcomes in adults with congenital heart disease: An international study.</bold>
<italic>Heart Rhythm</italic>. 2020; 17(5):768-76. DOI: 10.1016/j.hrthm.2019.11.026</mixed-citation>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lévesque</surname>
<given-names>V</given-names>
</name>
<name>
<surname>Laplante</surname>
<given-names>L</given-names>
</name>
<name>
<surname>Shohoudi</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Apers</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Kovacs</surname>
<given-names>AH</given-names>
</name>
<name>
<surname>Luyckx</surname>
<given-names>K</given-names>
</name>
</person-group>
<article-title>Implantable cardioverter-defibrillators and patient-reported outcomes in adults with congenital heart disease: An international study</article-title>
<source>Heart Rhythm</source>
<year>2020</year>
<volume>17</volume>
<issue>5</issue>
<fpage>768</fpage>
<lpage>776</lpage>
<pub-id pub-id-type="doi">10.1016/j.hrthm.2019.11.026</pub-id>
</element-citation>
</ref>
<ref id="redalyc_273865670003_ref11">
<label>11.</label>
<mixed-citation>11.	Willy K, Reinke F, Bögeholz N, Ellermann C, Rath B, Köbe J, et al. <bold>The role of entirely subcutaneous ICD™ systems in patients with dilated cardiomyopathy.</bold>
<italic>J Cardiol</italic>. 2020; 75(5):567-70. DOI: 10.1016/j.jjcc.2019.10.005</mixed-citation>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Willy</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Reinke</surname>
<given-names>F</given-names>
</name>
<name>
<surname>Bögeholz</surname>
<given-names>N</given-names>
</name>
<name>
<surname>Ellermann</surname>
<given-names>C</given-names>
</name>
<name>
<surname>Rath</surname>
<given-names>B</given-names>
</name>
<name>
<surname>Köbe</surname>
<given-names>J</given-names>
</name>
</person-group>
<article-title>The role of entirely subcutaneous ICD™ systems in patients with dilated cardiomyopathy</article-title>
<source>J Cardiol</source>
<year>2020</year>
<volume>75</volume>
<issue>5</issue>
<fpage>567</fpage>
<lpage>570</lpage>
<pub-id pub-id-type="doi">10.1016/j.jjcc.2019.10.005</pub-id>
</element-citation>
</ref>
<ref id="redalyc_273865670003_ref12">
<label>12.</label>
<mixed-citation>12.	Stolfo D, Albani S, Savarese G, Barbati G, Ramani F, Gigli M, et al. <bold>Risk of sudden cardiac death in New York Heart Association class I patients with dilated cardiomyopathy: A competing risk analysis</bold>. <italic>Int J Cardio</italic>. 2020; 307:75-81. 	DOI: 10.1016/j.ijcard.2020.02.025</mixed-citation>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Stolfo</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Albani</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Savarese</surname>
<given-names>G</given-names>
</name>
<name>
<surname>Barbati</surname>
<given-names>G</given-names>
</name>
<name>
<surname>Ramani</surname>
<given-names>F</given-names>
</name>
<name>
<surname>Gigli</surname>
<given-names>M</given-names>
</name>
</person-group>
<article-title>Risk of sudden cardiac death in New York Heart Association class I patients with dilated cardiomyopathy: A competing risk analysis</article-title>
<source>Int J Cardio</source>
<year>2020</year>
<volume>307</volume>
<fpage>75</fpage>
<lpage>81</lpage>
<pub-id pub-id-type="doi">10.1016/j.ijcard.2020.02.025</pub-id>
</element-citation>
</ref>
<ref id="redalyc_273865670003_ref13">
<label>13.</label>
<mixed-citation>13.	Arango-Franco R, Cárdenas-Castellanos JM, Rivera-Toquica A, Martínez JW, Marín-Medina DS, Orozco-Hernández JP, et al. <bold>Terapia de resincronización cardíaca con o sin cardiodesfibrilador versus terapia con desfibrilador automático, Pereira (Colombia): un estudio de cohorte</bold>. <italic>Iatreia</italic>. 2016; 29:133-43. 			DOI: 10.17533/udea.iatreia.v29n2a03</mixed-citation>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Arango-Franco</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Cárdenas-Castellanos</surname>
<given-names>JM</given-names>
</name>
<name>
<surname>Rivera-Toquica</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Martínez</surname>
<given-names>JW</given-names>
</name>
<name>
<surname>Marín-Medina</surname>
<given-names>DS</given-names>
</name>
<name>
<surname>Orozco-Hernández</surname>
<given-names>JP</given-names>
</name>
</person-group>
<article-title>Terapia de resincronización cardíaca con o sin cardiodesfibrilador versus terapia con desfibrilador automático, Pereira (Colombia): un estudio de cohorte</article-title>
<source>Iatreia</source>
<year>2016</year>
<volume>29</volume>
<fpage>133</fpage>
<lpage>143</lpage>
<pub-id pub-id-type="doi">10.17533/udea.iatreia.v29n2a03</pub-id>
</element-citation>
</ref>
<ref id="redalyc_273865670003_ref14">
<label>14.</label>
<mixed-citation>14.	Brignole M, Auricchio A, Baron-Esquivias G, Bordachar P, Boriani G, Breithardt OA, et al. <bold>2013 ESC guidelines on cardiac pacing and cardiac resynchronization therapy: the task force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA).</bold>
<italic>Europace</italic>. 2013;15(8):1070-118. 			DOI: 10.1093/europace/eut206</mixed-citation>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Brignole</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Auricchio</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Baron-Esquivias</surname>
<given-names>G</given-names>
</name>
<name>
<surname>Bordachar</surname>
<given-names>P</given-names>
</name>
<name>
<surname>Boriani</surname>
<given-names>G</given-names>
</name>
<name>
<surname>Breithardt</surname>
<given-names>OA</given-names>
</name>
</person-group>
<article-title>Bordachar P, Boriani G, Breithardt OA, et al. 2013 ESC guidelines on cardiac pacing and cardiac resynchronization therapy: the task force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA)</article-title>
<source>Europace</source>
<year>2013</year>
<volume>15</volume>
<issue>8</issue>
<fpage>1070</fpage>
<lpage>1118</lpage>
<pub-id pub-id-type="doi">10.1093/europace/eut206</pub-id>
</element-citation>
</ref>
<ref id="redalyc_273865670003_ref15">
<label>15.</label>
<mixed-citation>15.	Exner DV, Birnie DH, Moe G, Thibault B, Philippon F, Healey JS, et al. <bold>Canadian Cardiovascular Society guidelines on the use of cardiac resynchronization therapy: evidence and patient selection</bold>. <italic>Can J Cardiol.</italic> 2013; 29(2):182-95. 	DOI: 10.1016/j.cjca.2012.10.006.</mixed-citation>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Exner</surname>
<given-names>DV</given-names>
</name>
<name>
<surname>Birnie</surname>
<given-names>DH</given-names>
</name>
<name>
<surname>Moe</surname>
<given-names>G</given-names>
</name>
<name>
<surname>Thibault</surname>
<given-names>B</given-names>
</name>
<name>
<surname>Philippon</surname>
<given-names>F</given-names>
</name>
<name>
<surname>Healey</surname>
<given-names>JS</given-names>
</name>
</person-group>
<article-title>Canadian Cardiovascular Society guidelines on the use of cardiac resynchronization therapy: evidence and patient selection</article-title>
<source>Can J Cardiol</source>
<year>2013</year>
<volume>29</volume>
<issue>2</issue>
<fpage>182</fpage>
<lpage>195</lpage>
<pub-id pub-id-type="doi">10.1016/j.cjca.2012.10.006</pub-id>
</element-citation>
</ref>
<ref id="redalyc_273865670003_ref16">
<label>16.</label>
<mixed-citation>16.	Gialama F, Prezerakos P, Maniadakis N. <bold>The cost effectiveness of implantable cardioverter defibrillators: a systematic review of economic evaluations.</bold>
<italic>Appl Health Econ Health Policy.</italic> 2014;12(1):41-9. DOI: 10.1007/s40258-013-0069-2</mixed-citation>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Gialama</surname>
<given-names>F</given-names>
</name>
<name>
<surname>Prezerakos</surname>
<given-names>P</given-names>
</name>
<name>
<surname>Maniadakis</surname>
<given-names>N</given-names>
</name>
</person-group>
<article-title>The cost effectiveness of implantable cardioverter defibrillators: a systematic review of economic evaluations</article-title>
<source>Appl Health Econ Health Policy</source>
<year>2014</year>
<volume>12</volume>
<issue>1</issue>
<fpage>41</fpage>
<lpage>49</lpage>
<pub-id pub-id-type="doi">10.1007/s40258-013-0069-2</pub-id>
</element-citation>
</ref>
<ref id="redalyc_273865670003_ref17">
<label>17.</label>
<mixed-citation>17.	Narbondo F, Pouso J, Varela G, Calleriza F, Do Mato G, Reyes-Caorsi W. <bold>Cardiodesfibriladores implantables: Diecinueve años de experiencia en un centro de nuestro país.</bold>
<italic>Rev Urug Cardiol</italic>. 2013; 28:141-50.</mixed-citation>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Narbondo</surname>
<given-names>F</given-names>
</name>
<name>
<surname>Pouso</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Varela</surname>
<given-names>G</given-names>
</name>
<name>
<surname>Calleriza</surname>
<given-names>F</given-names>
</name>
<name>
<surname>Do Mato</surname>
<given-names>G</given-names>
</name>
<name>
<surname>Reyes-Caorsi</surname>
<given-names>W</given-names>
</name>
</person-group>
<article-title>Cardiodesfibriladores implantables: Diecinueve años de experiencia en un centro de nuestro país</article-title>
<source>Rev Urug Cardiol</source>
<year>2013</year>
<volume>28</volume>
<fpage>141</fpage>
<lpage>150</lpage>
</element-citation>
</ref>
<ref id="redalyc_273865670003_ref18">
<label>18.</label>
<mixed-citation>18.	Eknoyan G, Lameire N, Eckardt K, Kasiske B, Wheeler D, Levin A, et al. <bold>KDIGO 2012 clinical practice guideline for the evaluation and management of chronic kidney disease</bold>. <italic>Kidney Int</italic>. 2013: 3(1):5-14.</mixed-citation>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Eknoyan</surname>
<given-names>G</given-names>
</name>
<name>
<surname>Lameire</surname>
<given-names>N</given-names>
</name>
<name>
<surname>Eckardt</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Kasiske</surname>
<given-names>B</given-names>
</name>
<name>
<surname>Wheeler</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Levin</surname>
<given-names>A</given-names>
</name>
</person-group>
<article-title>KDIGO 2012 clinical practice guideline for the evaluation and management of chronic kidney disease</article-title>
<source>Kidney Int</source>
<year>2013</year>
<volume>3</volume>
<issue>1</issue>
<fpage>5</fpage>
<lpage>14</lpage>
</element-citation>
</ref>
<ref id="redalyc_273865670003_ref19">
<label>19.</label>
<mixed-citation>19.	Arango-Franco R, Martínez JW, Cárdenas-Castellanos JM, Rivera-Toquica AA, Marín-Medina DS, Orozco-Hernández JP, et al. <bold>Falla cardíaca avanzada en pacientes tratados con dispositivos electrofisiológicos en una unidad de electrofisología, Pereira (Colombia). </bold>
<italic>Investigaciones Andina.</italic> 2014; 16:978-88. DOI: 10.33132/01248146.76</mixed-citation>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Arango-Franco</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Martínez</surname>
<given-names>JW</given-names>
</name>
<name>
<surname>Cárdenas-Castellanos</surname>
<given-names>JM</given-names>
</name>
<name>
<surname>Rivera-Toquica</surname>
<given-names>AA</given-names>
</name>
<name>
<surname>Marín-Medina</surname>
<given-names>DS</given-names>
</name>
<name>
<surname>Orozco-Hernández</surname>
<given-names>JP</given-names>
</name>
</person-group>
<article-title>Falla cardíaca avanzada en pacientes tratados con dispositivos electrofisiológicos en una unidad de electrofisología, Pereira (Colombia)</article-title>
<source>Investigaciones Andina</source>
<year>2014</year>
<volume>16</volume>
<fpage>978</fpage>
<lpage>988</lpage>
<pub-id pub-id-type="doi">10.33132/01248146.76</pub-id>
</element-citation>
</ref>
<ref id="redalyc_273865670003_ref20">
<label>20.</label>
<mixed-citation>20.	Rosso F, Perafán-Bautista PE, Carrillo-Gómez DC, Ramos-Amézquita MH, Cedano-Rincón J.<bold> Infección relacionada con los dispositivos cardiovasculares</bold>. <italic>Rev Col Cardiol.</italic> 2016; 23:508-13. 	DOI: 10.1016/j.rccar.2016.07.005</mixed-citation>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Rosso</surname>
<given-names>F</given-names>
</name>
<name>
<surname>Perafán-Bautista</surname>
<given-names>PE</given-names>
</name>
<name>
<surname>Carrillo-Gómez</surname>
<given-names>DC</given-names>
</name>
<name>
<surname>Ramos-Amézquita</surname>
<given-names>MH</given-names>
</name>
<name>
<surname>Cedano-Rincón</surname>
<given-names>J</given-names>
</name>
</person-group>
<article-title>Infección relacionada con los dispositivos cardiovasculares</article-title>
<source>Rev Col Cardiol</source>
<year>2016</year>
<volume>23</volume>
<fpage>508</fpage>
<lpage>513</lpage>
<pub-id pub-id-type="doi">10.1016/j.rccar.2016.07.005</pub-id>
</element-citation>
</ref>
<ref id="redalyc_273865670003_ref21">
<label>21.</label>
<mixed-citation>21.	Ponikowski P, Voors AA, Anker SD, Bueno H, Cleland JGF, Coats AJS, et al. <bold>2016 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure: The Task Force for the diagnosis and treatment of acute and chronic heart failure of the European Society of Cardiology (ESC)Developed with the special contribution of the Heart Failure Association (HFA) of the ESC.</bold>
<italic>Eur Heart J.</italic> 2016; 37(27):2129-200. 	DOI: 10.1093/eurheartj/ehw128</mixed-citation>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ponikowski</surname>
<given-names>P</given-names>
</name>
<name>
<surname>Voors</surname>
<given-names>AA</given-names>
</name>
<name>
<surname>Anker</surname>
<given-names>SD</given-names>
</name>
<name>
<surname>Bueno</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Cleland</surname>
<given-names>JGF</given-names>
</name>
<name>
<surname>Coats</surname>
<given-names>AJS</given-names>
</name>
</person-group>
<article-title>2016 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure: The Task Force for the diagnosis and treatment of acute and chronic heart failure of the European Society of Cardiology (ESC)Developed with the special contribution of the Heart Failure Association (HFA) of the ESC</article-title>
<source>Eur Heart J</source>
<year>2016</year>
<volume>37</volume>
<issue>27</issue>
<fpage>2129</fpage>
<lpage>2200</lpage>
<pub-id pub-id-type="doi">10.1093/eurheartj/ehw128</pub-id>
</element-citation>
</ref>
<ref id="redalyc_273865670003_ref22">
<label>22.</label>
<mixed-citation>22.	Levey AS, Stevens LA, Schmid CH, Zhang YL, Castro AF, 3rd, Feldman HI, et al. <bold>A new equation to estimate glomerular filtration rate</bold>. <italic>Ann intern Med.</italic> 2009; 150(9):604-12.</mixed-citation>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Levey</surname>
<given-names>AS</given-names>
</name>
<name>
<surname>Stevens</surname>
<given-names>LA</given-names>
</name>
<name>
<surname>Schmid</surname>
<given-names>CH</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>YL</given-names>
</name>
<name>
<surname>Castro</surname>
<given-names>AF</given-names>
</name>
<name>
<surname>Feldman</surname>
<given-names>HI</given-names>
</name>
</person-group>
<article-title>A new equation to estimate glomerular filtration rate</article-title>
<source>Ann intern Med</source>
<year>2009</year>
<volume>150</volume>
<issue>9</issue>
<fpage>604</fpage>
<lpage>612</lpage>
</element-citation>
</ref>
<ref id="redalyc_273865670003_ref23">
<label>23.</label>
<mixed-citation>23.	Cox C, Chu H, Schneider MF, Muñoz A. <bold>Parametric survival analysis and taxonomy of hazard functions for the generalized gamma distribution</bold>. <italic>Stat Med.</italic> 2007; 26(23):4352-74. DOI: 10.1002/sim.2836</mixed-citation>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Cox</surname>
<given-names>C</given-names>
</name>
<name>
<surname>Chu</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Schneider</surname>
<given-names>MF</given-names>
</name>
<name>
<surname>Muñoz</surname>
<given-names>A</given-names>
</name>
</person-group>
<article-title>Parametric survival analysis and taxonomy of hazard functions for the generalized gamma distribution</article-title>
<source>Stat Med</source>
<year>2007</year>
<volume>26</volume>
<issue>23</issue>
<fpage>4352</fpage>
<lpage>4574</lpage>
<pub-id pub-id-type="doi">10.1002/sim.2836</pub-id>
</element-citation>
</ref>
<ref id="redalyc_273865670003_ref24">
<label>24.</label>
<mixed-citation>24.	CIBIS-II Investigators. <bold>The Cardiac Insufficiency Bisoprolol Study II (CIBIS-II): a randomised trial</bold>. <italic>Lancet.</italic> 1999; 353(9146):9-13. 		DOI: 10.1016/S0140-6736(98)11181-9</mixed-citation>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<collab>CIBIS-II Investigators</collab>
</person-group>
<article-title>The Cardiac Insufficiency Bisoprolol Study II (CIBIS-II): a randomised trial</article-title>
<source>Lancet</source>
<year>1999</year>
<volume>353</volume>
<issue>9146</issue>
<fpage>9</fpage>
<lpage>13</lpage>
<pub-id pub-id-type="doi">10.1016/S0140-6736(98)11181-9</pub-id>
</element-citation>
</ref>
<ref id="redalyc_273865670003_ref25">
<label>25.</label>
<mixed-citation>25.	Poole-Wilson PA, Swedberg K, Cleland JG, Di Lenarda A, Hanrath P, Komajda M, et al. <bold>Comparison of carvedilol and metoprolol on clinical outcomes in patients with chronic heart failure in the Carvedilol Or Metoprolol European Trial (COMET): randomised controlled trial</bold>.<italic> Lancet</italic>. 2003; 362(9377):7-13. 			DOI: 10.1016/S0140-6736(03)13800-7</mixed-citation>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Poole-Wilson</surname>
<given-names>PA</given-names>
</name>
<name>
<surname>Swedberg</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Cleland</surname>
<given-names>JG</given-names>
</name>
<name>
<surname>Di Lenarda</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Hanrath</surname>
<given-names>P</given-names>
</name>
<name>
<surname>Komajda</surname>
<given-names>M</given-names>
</name>
</person-group>
<article-title>Comparison of carvedilol and metoprolol on clinical outcomes in patients with chronic heart failure in the Carvedilol Or Metoprolol European Trial (COMET): randomised controlled trial</article-title>
<source>Lancet</source>
<year>2003</year>
<volume>362</volume>
<issue>9377</issue>
<fpage>7</fpage>
<lpage>13</lpage>
<pub-id pub-id-type="doi">10.1016/S0140-6736(03)13800-7</pub-id>
</element-citation>
</ref>
<ref id="redalyc_273865670003_ref26">
<label>26.</label>
<mixed-citation>26.	Packer M, Coats AJS, Fowler MB, Katus HA, Krum H, Mohacsi P, et al. <bold>Effect of Carvedilol on Survival in Severe Chronic Heart Failure</bold>. <italic>N Engl J Med</italic>. 2001; 344(22):1651-8. 		DOI: 10.1056/NEJM200105313442201</mixed-citation>
<element-citation publication-type="book">
<person-group person-group-type="author">
<name>
<surname>Packer</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Coats</surname>
<given-names>AJS</given-names>
</name>
<name>
<surname>Fowler</surname>
<given-names>MB</given-names>
</name>
<name>
<surname>Katus</surname>
<given-names>HA</given-names>
</name>
<name>
<surname>Krum</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Mohacsi</surname>
<given-names>P</given-names>
</name>
</person-group>
<article-title>Effect of Carvedilol on Survival in Severe Chronic Heart Failure</article-title>
<source>N Engl J Med</source>
<year>2001</year>
<volume>344</volume>
<issue>22</issue>
<fpage>1651</fpage>
<lpage>1658</lpage>
<pub-id pub-id-type="doi">10.1056/NEJM200105313442201</pub-id>
</element-citation>
</ref>
<ref id="redalyc_273865670003_ref27">
<label>27.</label>
<mixed-citation>27.	Bode-Schnurbus L, Böcker D, Block M, Gradaus R, Heinecke A, Breithardt G, et al. <bold>QRS duration: a simple marker for predicting cardiac mortality in ICD patients with heart failure</bold>. <italic>Heart.</italic> 2003; 89(10):1157-62. DOI: 10.1136/heart.89.10.1157</mixed-citation>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bode-Schnurbus</surname>
<given-names>L</given-names>
</name>
<name>
<surname>Böcker</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Block</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Gradaus</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Heinecke</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Breithardt</surname>
<given-names>G</given-names>
</name>
</person-group>
<article-title>QRS duration: a simple marker for predicting cardiac mortality in ICD patients with heart failure</article-title>
<source>Heart</source>
<year>2003</year>
<volume>89</volume>
<issue>10</issue>
<fpage>1157</fpage>
<lpage>1162</lpage>
<pub-id pub-id-type="doi">10.1136/heart.89.10.1157</pub-id>
</element-citation>
</ref>
<ref id="redalyc_273865670003_ref28">
<label>28.</label>
<mixed-citation>28.	Kashani A, Barold SS. <bold>Significance of QRS Complex Duration in Patients With Heart Failure</bold>. <italic>J Am Coll Cardiol.</italic> 2005; 46(12):2183-92. 	DOI: 10.1016/j.jacc.2005.01.071</mixed-citation>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kashani</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Barold</surname>
<given-names>SS</given-names>
</name>
</person-group>
<article-title>Significance of QRS Complex Duration in Patients With Heart Failure</article-title>
<source>J Am Coll Cardiol</source>
<year>2005</year>
<volume>89</volume>
<issue>10</issue>
<fpage>1157</fpage>
<lpage>1162</lpage>
<pub-id pub-id-type="doi">10.1136/heart.89.10.1157</pub-id>
</element-citation>
</ref>
<ref id="redalyc_273865670003_ref29">
<label>29.</label>
<mixed-citation>29.	Lelakowski J, Piekarz J, Rydlewska A, Majewski J, Senderek T, Ząbek A, et al. <bold>Determinants of patient survival rate after implantation of a cardioverter-defibrillator without resynchronisation capability.</bold>
<italic>Kardiol Pol</italic>. 2012; 70(11):1099-110.</mixed-citation>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lelakowski</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Piekarz</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Rydlewska</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Majewski</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Senderek</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Ząbek</surname>
<given-names>A</given-names>
</name>
</person-group>
<article-title>Determinants of patient survival rate after implantation of a cardioverter-defibrillator without resynchronisation capability</article-title>
<source>Kardiol Pol</source>
<year>2012</year>
<volume>70</volume>
<issue>11</issue>
<fpage>1099</fpage>
<lpage>1110</lpage>
</element-citation>
</ref>
<ref id="redalyc_273865670003_ref30">
<label>30.</label>
<mixed-citation>30.	Chamberlain AM, Redfield MM, Alonso A, Weston SA, Roger VL. <bold>Atrial fibrillation and mortality in heart failure: a community study.</bold>
<italic>Circ Heart Fail.</italic> 2011; 4(6):740-6. 			DOI: 10.1161/CIRCHEARTFAILURE.111.962688</mixed-citation>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Chamberlain</surname>
<given-names>AM</given-names>
</name>
<name>
<surname>Redfield</surname>
<given-names>MM</given-names>
</name>
<name>
<surname>Alonso</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Weston</surname>
<given-names>SA</given-names>
</name>
<name>
<surname>Roger</surname>
<given-names>VL</given-names>
</name>
</person-group>
<article-title>Atrial fibrillation and mortality in heart failure: a community study</article-title>
<source>Circ Heart Fail</source>
<year>2011</year>
<volume>4</volume>
<issue>6</issue>
<fpage>740</fpage>
<lpage>746</lpage>
<pub-id pub-id-type="doi">10.1161/CIRCHEARTFAILURE.111.962688</pub-id>
</element-citation>
</ref>
<ref id="redalyc_273865670003_ref31">
<label>31.</label>
<mixed-citation>31.	Kotecha D, Piccini JP. <bold>Atrial fibrillation in heart failure: what should we do?</bold>
<italic>Eur Heart J</italic>. 2015; 36(46):3250-7. DOI: 10.1093/eurheartj/ehv513</mixed-citation>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kotecha</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Piccini</surname>
<given-names>JP</given-names>
</name>
</person-group>
<article-title>Atrial fibrillation in heart failure: what should we do?</article-title>
<source>Eur Heart J</source>
<year>2015</year>
<volume>36</volume>
<issue>46</issue>
<fpage>3250</fpage>
<lpage>3257</lpage>
<pub-id pub-id-type="doi">10.1093/eurheartj/ehv513</pub-id>
</element-citation>
</ref>
<ref id="redalyc_273865670003_ref32">
<label>32.</label>
<mixed-citation>32.	Cadrin-Tourigny J, Shohoudi A, Roy D, Talajic M, Tadros R, Mondésert B, et al. <bold>Decreased Mortality With Beta-Blockers in Patients With Heart Failure and Coexisting Atrial Fibrillation: An AF-CHF Substudy.</bold>
<italic>JACC Heart fail</italic>. 2017; 5(2):99-106. DOI: 10.1016/j.jchf.2016.10.015</mixed-citation>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Cadrin-Tourigny</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Shohoudi</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Roy</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Talajic</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Tadros</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Mondésert</surname>
<given-names>B</given-names>
</name>
</person-group>
<article-title>Decreased Mortality With Beta-Blockers in Patients With Heart Failure and Coexisting Atrial Fibrillation: An AF-CHF Substudy</article-title>
<source>JACC Heart fail</source>
<year>2017</year>
<volume>5</volume>
<issue>2</issue>
<fpage>99</fpage>
<lpage>106</lpage>
<pub-id pub-id-type="doi">10.1016/j.jchf.2016.10.015</pub-id>
</element-citation>
</ref>
<ref id="redalyc_273865670003_ref33">
<label>33.</label>
<mixed-citation>33.	Yancy CW, Jessup M, Bozkurt B, Butler J, Casey DE, Colvin MM, et al. <bold>2016 ACC/AHA/HFSA Focused Update on New Pharmacological Therapy for Heart Failure: An Update of the 2013 ACCF/AHA Guideline for the Management of Heart Failure: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Failure Society of America</bold>. <italic>Circulation</italic>. 2016; 134(13):e282-e93. 			DOI: 10.1161/CIR.0000000000000435</mixed-citation>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Yancy</surname>
<given-names>CW</given-names>
</name>
<name>
<surname>Jessup</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Bozkurt</surname>
<given-names>B</given-names>
</name>
<name>
<surname>Butler</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Casey</surname>
<given-names>DE</given-names>
</name>
<name>
<surname>Colvin</surname>
<given-names>MM</given-names>
</name>
</person-group>
<article-title>2016 ACC/AHA/HFSA Focused Update on New Pharmacological Therapy for Heart Failure: An Update of the 2013 ACCF/AHA Guideline for the Management of Heart Failure: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Failure Society of America</article-title>
<source>Circulation</source>
<year>2016</year>
<volume>134</volume>
<issue>13</issue>
<fpage>e282</fpage>
<lpage>e293</lpage>
<pub-id pub-id-type="doi">10.1161/CIR.0000000000000435</pub-id>
</element-citation>
</ref>
<ref id="redalyc_273865670003_ref34">
<label>34.</label>
<mixed-citation>34.	Mitchell LB, Pineda EA, Titus JL, Bartosch PM, Benditt DG. <bold>Sudden death in patients with implantable cardioverter defibrillators: the importance of post-shock electromechanical dissociation.</bold>
<italic>J Am Coll Cardiol.</italic> 2002; 39(8):1323-8. DOI: 10.1016/s0735-1097(02)01784-9</mixed-citation>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Mitchell</surname>
<given-names>LB</given-names>
</name>
<name>
<surname>Pineda</surname>
<given-names>EA</given-names>
</name>
<name>
<surname>Titus</surname>
<given-names>JL</given-names>
</name>
<name>
<surname>Bartosch</surname>
<given-names>PM</given-names>
</name>
<name>
<surname>Benditt</surname>
<given-names>DG</given-names>
</name>
</person-group>
<article-title>Sudden death in patients with implantable cardioverter defibrillators: the importance of post-shock electromechanical dissociation</article-title>
<source>J Am Coll Cardiol</source>
<year>2002</year>
<volume>39</volume>
<issue>8</issue>
<fpage>1323</fpage>
<lpage>1328</lpage>
<pub-id pub-id-type="doi">10.1016/s0735-1097(02)01784-9</pub-id>
</element-citation>
</ref>
<ref id="redalyc_273865670003_ref35">
<label>35.</label>
<mixed-citation>35.	Perilla-Orozco DM, Pantoja-Molina AD, Sánchez-Duque JA. <bold>Abordaje integral del adulto mayor: Una mirada desde la atención primaria</bold>. <italic>Aten Fam.</italic> 2020;27-(2):109-110. 			DOI: 10.22201/facmed.14058871p.2020.2.75205</mixed-citation>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Perilla-Orozco</surname>
<given-names>DM</given-names>
</name>
<name>
<surname>Pantoja-Molina</surname>
<given-names>AD</given-names>
</name>
<name>
<surname>Sánchez-Duque</surname>
<given-names>JA</given-names>
</name>
</person-group>
<article-title>Abordaje integral del adulto mayor: Una mirada desde la atención primaria</article-title>
<source>Aten Fam</source>
<year>2020</year>
<volume>27</volume>
<issue>2</issue>
<fpage>109</fpage>
<lpage>110</lpage>
<pub-id pub-id-type="doi">10.22201/facmed.14058871p.2020.2.75205</pub-id>
</element-citation>
</ref>
<ref id="redalyc_273865670003_ref36">
<label>36.</label>
<mixed-citation>36.	Sánchez-Duque JA, Blanco-Betancur M, Betancourt-Quevedo R, Issa-Sánchez MA. <bold>Cuidados al final de la vida y eutanasia en Colombia</bold>.<italic> Discover Medicine</italic>. 2019;3(1):11-12.</mixed-citation>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sánchez-Duque</surname>
<given-names>JA</given-names>
</name>
<name>
<surname>Blanco-Betancur</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Betancourt-Quevedo</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Issa-Sánchez</surname>
<given-names>MA</given-names>
</name>
</person-group>
<article-title>Cuidados al final de la vida y eutanasia en Colombia</article-title>
<source>Discover Medicine</source>
<year>2019</year>
<volume>3</volume>
<issue>1</issue>
<fpage>11</fpage>
<lpage>12</lpage>
</element-citation>
</ref>
<ref id="redalyc_273865670003_ref37">
<label>37.</label>
<mixed-citation>37. 	Pantoja-Molina AD, Perilla-Orozco DM, Sánchez-Duque JA. <bold>Prescripción inapropiada en adultos mayores: Una mirada desde la atención primaria</bold>
<italic>. Rev Clin Med Fam</italic>. 2020; 13(2):171-172.</mixed-citation>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Pantoja-Molina</surname>
<given-names>AD</given-names>
</name>
<name>
<surname>Perilla-Orozco</surname>
<given-names>DM</given-names>
</name>
<name>
<surname>Sánchez-Duque</surname>
<given-names>JA</given-names>
</name>
</person-group>
<article-title>Prescripción inapropiada en adultos mayores: Una mirada desde la atención primaria</article-title>
<source>Rev Clin Med Fam</source>
<year>2020</year>
<volume>13</volume>
<issue>2</issue>
<fpage>171</fpage>
<lpage>172</lpage>
</element-citation>
</ref>
</ref-list>
</back>
</article>